How to Install Pro-face HMI Software: Complete Step-by-Step Guide

In the world of industrial automation, Pro-face HMI software stands as one of the most reliable and user-friendly tools for creating and managing Human Machine Interface (HMI) applications. Whether you’re setting up a new system or upgrading an existing one, installing the Pro-face HMI software properly is crucial to ensure optimal performance and communication with PLCs, drives, and other automation devices.

In this detailed guide, we’ll show you how to install Pro-face HMI software on your Windows PC, along with helpful tips, system requirements, and troubleshooting advice. By the end of this article, you’ll be ready to design, configure, and monitor your industrial control systems like a professional.

What Is Pro-face HMI Software?

Pro-face HMI software, also known as GP-Pro EX, is a powerful and flexible development platform used to program and design HMI screens for Pro-face HMIs. It allows engineers and automation professionals to connect, visualize, and control industrial devices efficiently.

The software supports multiple communication protocols and easily integrates with PLC brands like Siemens, Mitsubishi, Omron, Delta, Allen-Bradley, Fatek, Panasonic, Fuji Electric, LG, Exor, Xinje, Vigor, Koyo, Inovance, Idec, and Hitech.

If you are looking to download GP-Pro EX or Pro-face HMI software, you can find the full version available on our website plcunlock.com – your trusted source for all unlocked PLC, HMI, and VFD software.

System Requirements for Installing Pro-face HMI Software

Before beginning the installation, ensure your PC meets the following system requirements for smooth and stable operation.

Minimum Requirements:

  • Operating System: Windows 7 / 8 / 10 / 11 (32-bit or 64-bit)
  • Processor: Intel Core i3 or higher
  • RAM: 4 GB minimum (8 GB recommended)
  • Hard Disk Space: 2 GB free space
  • Display Resolution: 1024 x 768 or higher
  • USB Port: For license dongle (if applicable)

Recommended Software Setup:

To achieve optimal performance and compatibility, ensure that:

  • Windows is fully updated
  • You have administrative rights
  • Antivirus is temporarily disabled during installation
  • .NET Framework 4.5 or higher is installed

Step-by-Step Guide: How to Install Pro-face HMI Software

Follow these steps carefully to install Pro-face HMI software on your computer.

Step 1: Download Pro-face HMI Software

Visit plcunlock.com and go to the HMI Software section. Locate the Pro-face HMI software (GP-Pro EX) download page.

At PLC Unlock, we provide:

  • Unlocked full versions
  • Lifetime activation
  • Fast download links (Google Drive / Mediafire)
  • Global technical support

Once you find the version you need (e.g., GP-Pro EX 4.09 or GP-Pro PBIII), click Download Now and save the installer file to your computer.

Step 2: Extract the Installation Files

After downloading, right-click the ZIP or RAR file and select “Extract Here” or “Extract to Folder” using WinRAR or 7-Zip.
You will find a setup file (usually named setup.exe or GPProEX_Setup.exe) and supporting installation files.

Step 3: Run the Setup as Administrator

Right-click the setup.exe file and choose “Run as Administrator”.
This ensures that the installer has permission to configure your system properly.

The installation wizard will start. Click Next to continue.

Step 4: Accept the License Agreement

Read the license agreement and click “I Agree” to proceed.
Select the installation path (we recommend the default directory, e.g., C:\Program Files (x86)\Pro-face\GP-Pro EX).

Step 5: Choose Installation Components

The setup may prompt you to select additional components such as:

  • Communication drivers (e.g., Siemens, Mitsubishi, Omron, Delta, etc.)
  • Language packs
  • Sample projects

Select all that are relevant to your PLC brand(s). This ensures full communication compatibility later.

Step 6: Begin Installation

Click Install to start the installation process.
Wait for a few minutes while the files are copied and configured on your system.

Once the installation completes, click Finish to close the wizard.

Step 7: Apply License or Activation

If you downloaded the unlocked version from plcunlock.com, your software is pre-activated and ready to use.

If you are using a trial version, you can enter your license key or apply the unlock patch provided with the download.

Step 8: Launch Pro-face HMI Software

Now, open Pro-face HMI Software from your desktop or Start Menu.
You’ll see the home interface where you can:

  • Create a new project
  • Select your HMI model
  • Configure PLC communication
  • Design custom screens and buttons
  • Download the project to your HMI device

Congratulations! You have successfully installed Pro-face HMI software.

How to Connect Pro-face HMI with PLC

Once installed, you can connect your Pro-face HMI with different PLCs. Here’s how:

  1. Open GP-Pro EX and create a new project.
  2. Select your HMI model from the list.
  3. Choose your PLC brand (for example, Siemens S7-200, Mitsubishi FX Series, Omron CJ1M, or Delta DVP Series).
  4. Set up the communication parameters – COM port, baud rate, parity, and station number.
  5. Click Transfer Project to download your configuration to the HMI panel.

Common Installation Issues and Fixes

Even though the installation is straightforward, some users face minor issues. Here’s how to resolve them:

  • Issue 1: Setup won’t start
    → Run as Administrator or disable antivirus temporarily.
  • Issue 2: Missing DLL or driver error
    → Install Microsoft Visual C++ Redistributable Packages and .NET Framework.
  • Issue 3: Software doesn’t detect PLC
    → Check your communication settings and ensure correct COM port selection.
  • Issue 4: Activation problem
    → Use the unlocked version provided by plcunlock.com for seamless activation.

Why Choose Pro-face HMI Software?

  • Easy-to-use interface for beginners and professionals.
  • Multi-brand PLC communication support.
  • High-quality visualization and control functions.
  • Advanced data logging, trending, and alarm handling.
  • Compatibility with a wide range of industrial devices.

Other Popular HMI and PLC Software You Can Explore

At plcunlock.com, we provide free and unlocked software downloads for various automation brands. You can explore related posts and download links for:

  • Siemens Step 7 MicroWIN V4.0
  • Delta DOPSoft V4.0 and V4.11.22
  • Mitsubishi GX Developer / GX Works2 / GX Works3
  • Allen-Bradley RSLogix 500 / 5000 / Studio 5000
  • Omron CX-Programmer / CX-Designer
  • Panasonic FPWIN Pro
  • Fuji Electric Hakko HMI Software (V-SFT)
  • Fatek WinProLadder
  • Weintek EasyBuilder Pro
  • Exor Designer Studio
  • Vigor HMI Software
  • Xinje Developer Software
  • Inovance HMI Editor
  • Idec WindO/I-NV2
  • Hitech HMI Software (ADP Series)

By linking these related posts, you help users discover more tools while improving your site’s SEO interlinking and ranking authority.

Final Thoughts

Installing Pro-face HMI software is a simple yet essential step for anyone working in automation and industrial control. By following the above guide, you can easily set up, activate, and start designing your HMI screens in no time.

At PLC Unlock, we make it easier for engineers, technicians, and automation professionals by providing unlocked, full-version software for all major PLC, HMI, and VFD brands.

If you need:

  • Free download links
  • License keys
  • Installation help
  • PLC and HMI programming tools

Then visit plcunlock.com – your ultimate destination for automation software.

Facebook
Twitter
LinkedIn

Add comment

Your email address will not be published. Required fields are marked